Form Factor |
2U Rackmount Chassis |
M/B Form Factor |
Motherboard MAX 12"x13". Customer Specified (OEM Available) |
Dimensions (Dx Wx H) |
650 x 437.5 x 88(mm) |
Material |
High quality Anti-finger 1.0 mm SGCC& Super ABS ROSHs |
Front Control |
1x Power On/Off, 1x System Reset, 1 x Unit Identification (UID) button,2 x USB 2.0 |
Indicators |
1x Power Status, 2x LAN Activity, 1x HDD Status,1x Fan Fail/System Over Heat LED 1 x Unit Identification (UID) LED |
Hotswap Backplane |
1)6GB SATA Hot-swap Backplane (Default) 2)6GB Mini SAS Hot-swap Backplane 3)12GB Mini SAS HD SGPIO Hot-swap Backplane |
Drive Bays |
External 3.5"/ 2.5":16 |
Cooling Fans |
Default 4x 80mm(T=28mm, up to 48mm), PWM 6x 30mm Fan Bays |
Expansion Slots |
7*half-height / 3*full-height |
PSU Form Factor |
2U single/redundant power supply. |
Color |
Front Panel Coated Black (Others customized) |
Application |
Cloud Storage, Cloud Computer, Huge Storage,Datacenters, NVR, Security Monitor Industry etc. |
Net Weight |
9.15Kg |
Gross Weight |
10.2Kgs |
Unit Carton Size |
21x80x59 cm |
Customized |
Available |
Order Code |
M/B |
HDD Backplane |
PSU |
Rear Window |
Slide Rail |
CS25606A6 |
12"x10.5" |
6-Bay 2.5"/3.5", 6GB SATA |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS25608A6 |
12"x10.5" |
8-Bay 2.5"/3.5", 6GB SATA |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS25608M6 |
12"x10.5" |
8-Bay 2.5"/3.5", 6GB mini SAS |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26508A6 |
12"x13" |
8-Bay 2.5"/3.5", 6GB SATA |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26508M6 |
12"x13" |
8-Bay 2.5"/3.5", 6GB mini SAS |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26508G12 |
12"x13" |
8-Bay 2.5"/3.5",12GB mini SAS HD SGPIO |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS25610A6 |
12"x10.5" |
10-Bay 2.5"/3.5", 6GB SATA |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26512M6 |
12"x13" |
12-Bay 2.5"/3.5", 6GB mini SAS |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26512G12 |
12"x13" |
12-Bay 2.5"/3.5",12GB mini SAS HD SGPIO |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CS26524G12 |
12"x13" |
24-Bay 2.5",12GB mini SAS HD SGPIO |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |
CT2558M6 |
12"x9.6" |
8-Bay 2.5"/3.5", 6GB mini SAS |
Option 500W/600 2U single 550W/650 2U Redundant |
7-Slot,HF (Option 3-Slot,FF) |
Option |